DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.
Taxonomy: TH- External Beam- Particle/high LET therapy: Range verification (in vivo/phantom): photoacoustic/optical
BReP-SNAP-T-118 | Range Verification of Pulsed Proton Beams From An FFA Via Ionoacoustic Measurement Y Nakamura1, T Uesaka1, T Takayanagi1,2, M Unlu1,3, Y Kuriyama4, Y Ishi4, T Uesugi4, M Kobayashi5, N Kudo1, S Tanaka1,K Umegaki1, T Matsuura1*, (1) Hokkaido University, JP, (2) Hitachi Ltd., JP, (3) Bogazici University, TR, (4) Kyoto University, JP, (5) Chiba Institute Of Technology, JP |
BReP-SNAP-T-121 | Resonant Ionoacoustic Measurement Under Clinical Dose: A Study Toward Online Range Verification T Takayanagi1,2*, T Uesaka1, Y Nakamura3, M B Unlu4,5, Y Kuriyama6, Y Ishi6, T Uesugi6, N Kudo7, M Kobayashi8, K Umegaki5,9,10, T Matsuura5,9,10, (1)Hokkaido University Graduate School of Biomedical Science and Engineering, Sapporo, Japan, (2)Hitachi Ltd., Hitachi, Japan, (3)Hokkaido University Graduate School of Engineering, Sapporo, Japan, (4)Bogazici University Department of Physics, Istanbul, Turkey, (5)Hokkaido University Global Institution for Collaborative Research and Education (GI-CoRE), Sapporo, Japan, (6)Kyoto University Institute for Integrated Radiation and Nuclear Science, Osaka, Japan, (7) Hokkaido University Faculty of Information Science and Technology, Sapporo, Japan, (8) Chiba Institute of Technology Planetary Exploration Research Center, Narashino, Japan, (9)Hokkaido University Faculty of Engineering, Sapporo, Japan, (10)Hokkaido University Hospital Proton Beam Therapy Center, Sapporo, Japan |
PO-GeP-T-689 | Range Determination for Proton Beams. A Comparison Between Luminescence Imaging in Water and Standard Ionization Chamber Based Methods J Burg1,2*, F Horst1, J Wulff4,5,6 H Vorwerk2, K Zink1,2,3, (1) University Medical Center Giessen-Marburg, Department of Radiotherapy and Radiooncology, Marburg, Germany (2) University of Applied Sciences, Institute of Medical Physics and Radiation Protection, Giessen, Germany (3) Marburg Ion-Beam Therapy Center (MIT), Marburg, Germany (4) West German Proton Therapy Centre Essen, Essen, Germany (5) West German Cancer Center (WTZ), Essen, Germany (6) Department of Particle Therapy, University Hospital Essen, Essen, Germany |
WE-A-TRACK 3-6 | Noise Reduction of Proton-Acoustic Signal for Proton Range Verification Using Stacked Auto-Encoder (SAE) J Sohn1*, Y Lei1, W Nie2, S Avery3, X Yang1, T Liu1, (1) Emory University, Atlanta, GA, (2) University of Nebraska, Omaha, NE, (3) University of Pennsylvania, Philadelphia, PA |